A GMP cell count you can prove,
not just trust.

The Moxi GO II is a benchtop cell analyzer for cell-therapy QC. It combines volumetric, physics-based counting with an on-instrument 21 CFR Part 11 audit trail (its Secure Mode module), so your count, viability, and identity check are accurate and easy to prove in the same at-line run.

21 CFR Part 11 via Secure Mode, no middleware User-swappable 2-color channel Zero-fluidics, no carryover
Talk to a Specialist Read the Penn Medicine data
Moxi GO II benchtop cell analyzer for cell-therapy QC

Start where the real decision is

When your counting step becomes a release assay, two benchtop counters can do the job: the Moxi GO II and a closed, prebuilt-stain GMP counter. Both are accurate. Head to head, they count equally well.

The decision comes down to what a closed counter cannot easily match: proving your count from day one, changing the phenotype marker yourself, and running each test on its own clean path, with no carryover between patient lots.

Three reasons to choose the Moxi GO II

1

Proof built in

21 CFR Part 11 via Secure Mode, no middleware

  • Secure Mode: every action logged, e-signature required
  • Role-based access; only an Admin can delete
  • An activated module on the instrument, not middleware to validate
2

A channel you can change

User-swappable 2-color fluorescence

  • Viability today, CD4 or CAR tomorrow
  • Same instrument, no second box to buy
  • A fixed-channel counter is a second purchase
3

Zero-fluidics, no carryover

Single-use cassette, one clean path

  • A new cassette every test
  • No shared fluid path, no carryover between lots
  • Self-calibrates on every run

The Moxi GO II earns its place when you need

  • A count you can prove
  • A phenotype you can change
  • A clean separation between patient lots

Where the two counters differ

An honest comparison against a closed GMP cell counter.

CapabilityMoxi GO IIA closed GMP counter
Count accuracy Volumetric, physics-based; equally accurate, validated Equally accurate
Count precision <2% CV (vs. 20–30% for image-based counters) Comparable
21 CFR Part 11 Secure Mode, an activated audit-trail module (no middleware) Varies; often added
Fluorescence User-swappable 2-color (viability + CD4 / CAR / transfection) Fixed channels
Consumable Single-use, zero-fluidics; no carryover Closed cassette
Count + viability + phenotype One at-line run, under 15 seconds Count-focused
Footprint 7 lb, at-line / near the biosafety cabinet Benchtop

Validated against the method you already trust

In a peer-reviewed CAR-T manufacturing QC study at Penn Medicine, the Moxi GO II showed no significant difference versus a reference volumetric sizer on count and size. Its viability and phenotype readouts correlated with a reference fluorescence analyzer, and its count precision is far tighter than image-based counters.

r²=0.97
viability vs. a reference analyzer
r²=0.997
CD4 readout
r²=0.90
CAR19 readout
<2% CV
count precision (vs. 20–30% imaging)

Pajarillo R, et al. Cytotherapy 2024;26(5):506–511. Count precision published by PCS.

Questions worth asking

How do I know the audit trail is real and captures deletions?

Secure Mode is a paid, activated audit-trail module — not on by default. Once enabled on the instrument, it logs every change, requires an e-signature, uses three access roles, and lets only an Admin delete. We will walk through it with you and bring the IQ/OQ package for your validation file.

Aren't a closed counter's prebuilt stains more consistent?

That is a real consistency argument. The Moxi GO II's strengths are proof and flexibility: 21 CFR Part 11 support through its Secure Mode module, a fluorescence channel you can swap, and a single-use cassette with no carryover.

Is two-color fluorescence enough for identity?

It is not meant to be a full panel. The Moxi GO II covers the routine at-line count, viability, and 1 to 2 color check, so your core analyzer is reserved for the high-parameter work only it can do.

Is the Moxi GO II the right fit for my lab?

It fits an at-line release workflow under 21 CFR Part 11, where you have to prove the count, swap the phenotype marker as your panel changes, and keep patient lots cleanly separated. If you need a full identity or potency panel, that belongs on a core-facility analyzer the Moxi GO II complements, and you will know quickly.

Make your counting step audit-ready

Talk to a specialist about your 21 CFR Part 11 release workflow. We will walk through the Secure Mode module with your team and bring the IQ/OQ and validation package.

Talk to a Specialist

For Research Use Only. Not for use in diagnostic procedures.

Concordance and precision data: Pajarillo R, et al. Cytotherapy 2024;26(5):506–511 (CAR-T manufacturing QC, Penn Medicine). Count-precision CV published by Precision Cell Systems.