A cell count you can prove
at CAR-T lot release.

The Moxi GO II is a benchtop cell analyzer for cell-therapy manufacturing QC. It reads count, viability, and a CD4 or CAR check in one at-line run. The result is accurate against your reference methods and audit-ready under 21 CFR Part 11, with no middleware project and no trip to the core.

21 CFR Part 11 Secure Mode Count, viability, CD4 / CAR in one run At-line, under 15 seconds
Talk to a Specialist See the Penn Medicine data
Moxi GO II benchtop cell analyzer
Cytotherapy 2024Peer-reviewed CAR-T manufacturing QC validation
40,000particles per test in ~15 seconds
<2% CVcount precision, vs 20–30% for imaging
21 CFR Part 11Secure Mode audit-trail module, no middleware

The counting step is the one your auditor questions first.

When the count becomes a release assay, every familiar way to count cells has a catch.

A manual count or a non-compliant bench counter.

No audit trail, and a number transcribed by hand. It will not survive the inspection.

An image-based counter.

Counts drift 20–30% on debris, clumps, and low concentrations, and the counter still is not 21 CFR Part 11.

Borrowed core-facility time.

A queue and a hand-off for every routine read, on an instrument built for high-parameter work you do not need here.

Compliance bolted onto a non-compliant counter with middleware.

A validation project of its own to stand up and keep current.

When the counting step fails the audit, the bill is a held release, a finding, and a re-validation, on a lot a patient is waiting for.

What the Moxi GO II gives cell-therapy QC.

A count you can prove

Secure Mode — the Moxi GO II's activated 21 CFR Part 11 audit-trail module — logs every action and requires an e-signature. Access spans three roles, and only an Admin can delete a record. No middleware to validate, and results export as FCS 3.1 that Quality and Manufacturing both open.

21 CFR Part 11 Secure Mode

A count you can trust

Volumetric, physics-based sizing measures each particle’s true volume, up to 40,000 per test. The count holds under 2% CV where image-based counts drift, and concords with the reference methods you already run.

<2% CV vs 20–30% imaging

Viability and phenotype in one run

The same under-15-second cassette reads live/dead and a CD4 or CAR marker alongside the count, so that check happens at-line instead of in a core booking.

Count + viability + phenotype, one run

Built to run at-line

A single-use, zero-fluidics cassette means no sheath fluid, no daily cleaning, and no carryover between patient lots. The 7-lb instrument self-calibrates every run and fits beside the biosafety cabinet.

7 lb · zero-fluidics cassette

Validated in CAR-T manufacturing QC at Penn Medicine.

In a peer-reviewed CAR-T manufacturing QC study, the Moxi GO II count and size showed no significant difference versus a reference volumetric sizer, and its viability and phenotype readouts tracked a reference fluorescence analyzer.

r²=0.97
viability vs. a reference analyzer
r²=0.997
CD4 readout
r²=0.90
CAR19 readout
<2% CV
count precision (vs. 20–30% imaging)

Pajarillo R, et al. Cytotherapy 2024;26(5):506–511 (DOI 10.1016/j.jcyt.2024.01.007). Count precision published by PCS.

Questions cell-therapy QC scientists ask.

Is the audit trail real, and does it capture deletions?

Secure Mode is a paid, activated audit-trail module — it ships off by default and is switched on with an activation code, not enabled out of the box. Once active, every data action is logged with an e-signature, access is role-based across three roles, and only an Admin can delete a record. It is a closed, on-device system, and an IQ/OQ package supports your validation file.

What is the regulatory status?

The Moxi GO II is for research use. Its 21 CFR Part 11 Secure Mode — a paid, activated module — gives the data integrity that GMP and GLP environments require for translational cell-therapy work.

What does it cost to run, and what is the real total?

Each test runs in a single-use cassette. The number that matters is cost per usable result. One instrument covers the routine count, viability, and a 1 to 2 color check, so a routine read no longer means a core booking.

Will it fit our workflow and data systems?

Results export as standard FCS 3.1 files that Quality and Manufacturing both open, and the 7-lb instrument runs at-line beside the biosafety cabinet.

What is the service and support model?

An IQ/OQ package and a tiered preventive-maintenance program back the GMP install.

Is two-color enough for identity?

It is not a full identity panel, and is not meant to be. The Moxi GO II handles the routine at-line count, viability, and a 1 to 2 color check, so your core analyzer is reserved for the high-parameter identity and potency work only it can do.

Bring your release workflow to a specialist.

A specialist will map the Moxi GO II to your 21 CFR Part 11 release workflow and bring the concordance data and the IQ/OQ validation package for your file.

Talk to a Specialist

For Research Use Only. Not for use in diagnostic procedures.

Concordance data from Pajarillo R, et al. Cytotherapy 2024;26(5):506–511 (DOI 10.1016/j.jcyt.2024.01.007). Count precision (<2% CV) published by Precision Cell Systems. 21 CFR Part 11 Secure Mode is a paid, activated audit-trail module, off by default until switched on with an activation code.